| 产品名称 | ABS-35-5 | ABS-35-12 | ABS-35-15 | ABS-35-24 | ABS-35-48 |
| 输出 | 直流电压 | 5V | 12V | 15V | 24V | 48V |
| 额定输出电流 | 6A | 3A | 2.4A | 1.5A | 0.76A |
| 输出电流范围 | 0~6A | 0~3A | 0~2.4A | 0~1.5A | 0~0.76A |
| 纹波噪声(注2) | 0~70℃ | <50mV | <80mV | <80mV | <120mV | <180 mV |
| 峰-峰值电压 | -25~0℃ | <80mV | <180mV | <180mV | <200mV | <240mV |
| 输出电压调节范围 | 4.75V-5.5V | 11.4V-13.2V | 14.25V-16.5V | 22.8V-26.4V | 45.6V-52.8V |
| 稳压精度 | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±3.0% |
| 源调整率 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| 负载调整率 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| 输出启动时间 | <1S (230Vac 输入, 满载); |
| 输出保持时间 | >20mS(230Vac 输入 满载); >10mS(120Vac 输入, 满载) |
| 温度系数 | ±0.03%/℃ |
| 电压过冲 | <5.0% |
| 输入 | 输入电压范围 | 90Vac~264Vac |
| 频率范围 | 47Hz~63Hz |
| 效率 (230Vac, 典型值) | 78% | 81% | 85% | 85% | 86% |
| 输入电流(最大值) | <1A |
| 启动冲击电流(典型值) | <50A@264Vac 电源冷机启动 |
| 保护功能 | 过流保护 | 6.3A~9A | 3.15A~4.5A | 2.52A~3.6A | 1.58A~2.25A | 0.80A~1.14A |
| 恒功率 | 恒功率 | 恒功率 | 恒功率 | 恒功率 |
| 过压保护 | 5.5V~7.5V恒压 | 13.2V~18V恒压 | 16.5V~22.5V恒压 | 26.4V~36V恒压 | 52.8V~72V恒压 |
| 短路保护 | 可长期短路,消除短路后可自动恢复 |
| 工作环境 | 工作温度及湿度 | -25℃~70℃; 20%~90%RH 不冷凝 (详情请参考降额曲线) |
| 储存温度及湿度. | -40℃~85℃; 10%~95%RH 不冷凝 |
| 安全及电磁 | 安全标准 | UL60950-1; EN60950-1 |
| 兼容标准注3 | 绝缘强度 | 输入-输出:3.0KVac; ≤10mA .输入-地1.5KVac; ≤10mA.输出-地:0.5KVDC;≤10mA. |
| 绝缘阻抗 | ≥100M ohms |
| 泄漏电流 | 输入对地≤3.5mA;输入对输出≤0.25mA |
| 电磁干扰 | Compliance to EN55022(CISPR22) ClassB |
| 谐波电流 | Compliance to EN61000-3-2 |
| 电磁抗干扰性 | Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,A级重工业标准 |
| 其他 | MTBF (MIL-HDBK-217F) | More than 200,000Hrs (25℃, 满载) |
| 尺寸 (长*宽*高) | 99×97×36mm |
| 冷却方式 | 自然风冷 |
|
| 注释 | 1. 如未特别说明,所有规格参数均在输入为230VAC、额定负载、25℃环境温度选进行量测 |
| 2. 纹波噪音测试方法: 使用一条12#双绞线,同时终端要并联0.1uF和10uF的电容,在示波器20MHz带宽下进行量测 |
| 3. 电源将会作为一个部件装在最终设备上,最终的设备仍需满足EMC条件. |