Features: Detects all HFC (134a) CFC refrigerants Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting Audible alarm and flashing light indicator upon gas leakage detected Inner precise I C with ultra-low consume circuit design, more stable, longer battery time Two color visual display of battery voltage Excellent sensor, high sensitivity, longer use time
Applications: Refrigerating systems Air conditioning units It responds to ALL halogenated (containing chlorine or fluorine) refrigerants, including: CFCs – eg. R11, R12, R500, R503 etc HCFCs – eg. R22, R123, R124, R502 HFCs – eg. R125, R134a, R404a Blends including AZ-50, HP62, MP39 etc Detect ethylene oxide gas leaks in hospital sterilizing equipment Detect SF-6 in high voltage circuit breakers Detect most gasses that contain chlorine, fluorine and bromine (halogen gasses) Detects cleaning agents used when dry cleaning such as perchloroethy Detects halogen gasses in fire extinguishing systems
电子卤素检漏仪是公司采用最新检漏技术,竭诚为您推出的一款实用新品。该机操作简便,性能稳定可靠,造型精致,是理想的经济型卤素检漏设备。
功能特点: 检测全部含卤素的制冷剂; 随时调节灵敏度,仪器均可自动调整到最佳检测状态;内置高精度稳压IC,并采用超低功耗设计,使工作更稳定,电池更耐用; 电池电压二色指示; 采用优质传感器,工作灵敏度高,寿命更长久
电池电压指示: 面板前端的指示灯用于警示泄漏及电池电压指示。 绿-电池电压正常,适于工作 橙-电池电压接近可工作极限,需要尽快更换 开机复位/自动跟随电路: 具有开机复位和自动跟随功能,可以忽略环境中卤素气体的浓度水平。 ◆开机复位:本仪器开机后,即可在6S内自动调整电路以忽略探头现存 的制冷剂浓度水平,进入检测状态,用户如在泄漏源旁开机,可方 便寻找更高浓度的泄漏源头。仪器也可移至清洁空气中开机,以调 整到最大灵敏度,此时高于零浓度水平的泄漏可被检出。 ◆自动跟随电路:在本仪器处于检测状态时,自动电路将跟随环境中卤 素气体浓度的变化,防止误报警。 灵敏度调节: 本产品具有灵敏度无级调节的功能,可在检测时随时调节。 泄漏量警示: 当泄漏的气体被发现,"嘀嘀"声将变的急促,泄漏量越多,"嘀嘀"声越急促。同时指示灯快闪。
性能指标: 工作温度: 0℃~52℃ 最大灵敏度: 对卤素制冷剂,6gr/yr 电池寿命: 正常使用下约50小时 响应时间: 瞬时 方 式: 无限制 探杆长度: 20cm 尺 寸: 22.9cm×6.5cm×6.5cm 预热时间: 约6秒 复位时间: 2-10秒 电 源: 6伏直流,4节7号优质电池
适用范围:
不仅可以用在汽车空调系统,还可以用在: ① 能够检测空调、冷冻系统和冷媒回收装置。仪器对所有的卤素气体(包括氯和氟)起反应,但还不局限这些: CFCs e.g.R12,R11,R500,R503 etc... HCFCs e.g.R22,R123,R124,R502 etc... HCFCs e.g.R134a,R404a,R125 etc... 还可检测其它混合物,如AZ-50,HP62,MP39,etc... ② 检测医用设备上的乙烯氧化物气体漏孔(检测卤素推进器); ③ 检测高压电路断路器中的SF-6; ④ 检测大部分氟、氯、溴(卤素气体); ⑤ 检测灭火系统中的哈龙气体。
Specification: Operating temperature:0°C to 52°C (30°F t 125°F) Maximum sensitivity: 6gr/yr for all halogenated refrigerants Battery life: approximately 50 hours normal use Response time: immediate Work mode: continuous – no limitations Fixed probe length: 20cm Unit dimensions: 15 x3 x 3 cm Warm-up time: approximately 6 seconds Reset time: 2 to 10 seconds Powered by: 2xAAA 1.5V batteries (not included)
Package Contents: 1 x Halogen Leak Detector with probe 1 x Instruction Sheet 1 x Black carrying pouch